May 2026

Hello, these are the May 2026 release notes for NDD Print. We have lots of new features, and we hope you like them.

Here you can download the latest versions.

Here is a summary of all the updates; click on the links to view each one.

NDD Print Host - 5.65.2

fixes

NDD Print MF Sharp - 5.4.5

IMPROVEMENTS

NDD Print Portal 360 - 5.80.0

IMPROVEMENTS

NDD Print Embedded Configuration Tool (ECT) - 1.11.1

IMPROVEMENTS

NDD Print MF HP - 5.31.7

fixes

NDD Print Tracer - 5.4.4

fixes


NDD Print Host - 5.65.2

Released on May 27, 2026

Fixes

Displaying the serial number of supplies on the Lexmark MX622adhe model

How did the problem happen?

The serial number of the supplies for the Lexmark MX622adhe model was not displayed during monitoring.

Where did the problem happen? 

When performing monitoring via NDD Print Host.

What was done to fix it?

An improvement has been made to the way serial numbers for supplies are retrieved. As a result, the system now correctly displays the serial number in most cases. However, some supplies may still not display this information due to limitations of the equipment itself.


NDD Print MF Sharp - 5.4.5

Released on May 18, 2026

Improvements

Blocking access to administrative functions on the NDD Print MF Sharp

The authentication process has been adjusted to block access attempts by unidentified users or those with invalid credentials. Access to administrative functions and web browsing has been restricted to appropriate scenarios only.


NDD Print Portal 360 - 5.80.0

Released on May 16, 2026

Improvements

Support for multiple domains: Enter ID

An update will be released for the NDD Print Portal 360 that will allow the use of more than one Entra ID domain per company.

Following this update, additional configuration in Azure business applications will be required for customers who already use the Entra ID integration and for new customers who adopt this feature.

Except for Selbetti customers. We will notify you in the future if any changes are needed.

Refer to the manual for instructions on how to perform this configuration: Microsoft Entra ID Domains - NDD Print SCIM Provisioning

If this configuration is not completed after the update is released, errors may occur during the import process.


NDD Print Embedded Configuration Tool (ECT) - 1.11.1

Released on May 14, 2026

Improvements

Visual improvements to management actions

We have improved the management interface for installation, configuration, activation, and deactivation of manufacturers.

Now, all these actions are centralized on a single page for each manufacturer, providing a more intuitive and organized navigation experience. In addition, the data entered is now preserved when navigating between actions, reducing rework and streamlining the process.


NDD Print MF HP - 5.31.7

Released on May 4, 2026

Fixes

Duplicating a directory in a customized path

How did the problem happen?

During installation, when changing only the drive letter of the default path (for example, from C: to D:) while keeping the original structure, the installer would duplicate the directory suffix. Example observed:

D:\Program Files\NDDigital\nddPrint\MF\HP\NDDigital\nddPrint\MF\HP

When did the problem occur?

This occurred during new installations, while setting the installation directory. It did not occur during updates.

Where did the problem happen? 

In the directory definition flow of the x64 installation, specifically during the validation of the final directory in the installation script.

What was done to fix it?

The conditional flow has been adjusted to prevent improper directory concatenation, ensuring that user-defined customized paths are correctly preserved without duplication.


NDD Print Tracer - 5.4.4

Released on May 4, 2026

Fixes

Incorrect language in reinstallation message

How did the problem happen?

When running the NDD Print Tracer installer in an environment where the same version was already installed, the system correctly blocked the installation; however, the message displayed to the user did not reflect the language configured in the previous installation and was displayed in the default language (e.g., English or Spanish).

When did the problem occur? 

This occurred when the installer was run again, in cases where the system was being reinstalled or when attempting to install the same version.

Where did the problem happen? 

During the installation process using the NSIS installer for the NDD Print Tracer module on Windows operating systems.

What was done to fix it?

Language identifier (LCID) persistence has been implemented in the Windows registry during installation. On subsequent runs, this information is retrieved to ensure that the displayed language matches the previously configured language.